LW8-40 deyò High-vòltaj brekè sikwi

Kout deskripsyon:

Espesifikasyon:10-200 USD / pyèsSèvi ak Pati:1 MOSÈKapasite Pwovizyon pou:1000 MOSÈRegleman Peman:TT, LC, lòt moun Tags:


Pwodwi detay

Pwodwi Tags

EstandaGB / T28001-2011 idt OHSAS18001: 2007


Aplikasyon

Actastheprotectingandcontrollingunitforgridequipmentsandindustrialminingenterprises'equipments, LW8-40.5 tip deyò SF6 sikwi brekè se yon aparèy deyò yo itilize nan AC 50HZ twa-faz 40.5KV pouvwa sistèm.Li aplikab a kote ki bezwen opere souvan nan rated aktyèl oswa anba repete sou / sou kouran sikwi kout. Ki gen transfòmatè aktyèl la pou mezi ak pwoteksyon, li ka dirèkteman ranplase SW2-35 mwens brekè sikwi lwil oliv ak divès kalite brekè sikwi lwil oliv ak bracket tranzisyon. Li kapab tou itilize kòm yon brekè menm kantite vòt ak chanje sitiyasyon gwoup kondansateur ak CT14 mekanis sezon prentan kalite.

Estanda

GB1984

GB / T28001-2011 idt OHSAS18001: 2007

GB / T24001-2004 idt ISO14001: 2004

Karakteristik

Ekselan pèfòmans kraze, kout boule tan arc, lavi ki long;

Lavi mekanik ki gen plis pase 3000 fwa;

Operasyon souvan, chak ka enstale 12 transfòmatè aktyèl;

Nouvo kalite SF6 MKZ konsèy tip dansite mèt, presyon kalib lekti pa afekte pa chanjman tanperati;

Kondisyon anviwònman an

Tanperati anbyen:-30 ℃ ~ + 40 ℃

Altitid: ≤3000m

Presyon van: ≤700Pa

Imidite relatif: chak jou mwayèn imidite relatif: ≤95%; chak mwa mwayèn imidite relatif≤90; chak jou mwayèn presyon satire vapè ≤2.2KPa; chak mwa mwayèn valè ≤1.8KPa

Nivo polisyon nan lè a: Ⅲ

Tranbleman tè entansite: ≤8 degre

Enstalasyon an ta dwe gratis nan dife, eksplozyon, Vibration grav, korozyon chimik ak polisyon grav

Main Paramèt teknik

Deskripsyon Inite Done
Ratedvoltage KV 40.5
Ratedinsulationlevel Lightningimpactwithstandvoltage (fullwavepeak) 185/215 (isolatingbreak)
1minpowerfrequencywithstandvoltage 95
Ratedcurrent A 1600 2000
Meachanicallife Fwa 3000
RatedSF6gaspressure (at20) Mpa 0.45
Self-lockingpressure (at20) 0.45
Lowestworkingambienttemperature -30
Ratedshortcircuitbreakingcurrent KA 25 31.5
Ratedshortcircuitmakingcurrent (pik) 63 80
Ratedshortwithstandcurrent (Thermalsteadycurrent) 25 31.5
Ratedpeakwithstandcurrent (dynamicsteadycurrent) 63 80
Ratedout-of-phasebreakingcurrent KA 63 80
Durationofratedshortcircuitcurrent S 4
Closingtime (atratedoperatingvoltage) ≤1
Ouvèti (atratedoperatingvoltage) ≤0.07
Ratedoperatingsequence (O) -0.3S- (CO) -180S- (CO)
Ratedbreaking / makingsiglecapacitorcurrent A 400
Nosofbreakingratedshortcircuitbreakingcurrent fwa 15 10
Yearlygasleakege % / ane ≤1
WatercontentinSF6 (at20) PPM (V) ≤150
Ratedvoltageofassembiedspringoperatingmechanism V -220
Voltageofclosingcoil, ouvèti bobin AC: 220
DC: 220
Voltageofchargingmotor V AC: 220
DC: 220
SF6Weight KG 8
Breakingweightincludingoperatingmechanism 1400

Remak: Tanpri kontakte faktori a konfime dènye paramèt yo